Sterling Air Cooled Servo Voltage Stabilizers are available for industrial, office & domestic applications. These are designed for precise control of output voltage (typically +/- 1%) that significantly increases life of appliances and machines as well as reduces breakdowns & maintenance.

Technical Specifications:

Rating / Capacity. 1KVA -15KVA
Input Voltage Range 170-270V, 140-270V, 110V-270V ( Other ranges on request )
Input Frequency 50 Hz. + / - 6%
Output Voltage 220/230/240V
Regulation + / - 1% for Line & Load variation (within Input Range & Load capacity)
Indications Mains ON
Input Voltage Low
Input voltage High
Other Indications for Optionals
Metering Voltmeter with selector switch to indicate Input / Output voltage
Optionals MCB on Input / Output
Output voltage high / Low cut off with Auto recovery
Output Overload Alarm / tripping with delay
Ammeter on Output
By pass switch.
General Specifications
Cooling Natural Air or Forced Ventilation or Oil Cooling (depending on rating)
Cabinet Table Top / Free standing (depending on rating)
Ambient Temp. 0 - 45 deg. C
Relative Humidity Max. 95% non condensing
Installation Indoor, in well ventilated space

Servo Voltage Stabilizers

Sterling Systems Sterling Systems




Air & Oil Cooled Three Phase Servo Stabilizers

Sterling Systems
Sterling Air and Oil Cooled Servo Voltage Stabilizers, Three Phase Servo Voltage Stabilizers, Servo Stabilizers are available for industrial, office & domestic applications. These are designed for precise control of output voltage (typically +/- 1%) that significantly increases life of appliances and machines as well as reduces breakdowns & maintenance.

Technical Specifications:

Rating / Capacity 3KVA - 100KVA
Input voltage Range 300-470V, 240-470V, 190-470V (Other range on request)
Type Unbalanced / Balanced
Input Frequency 50Hz + / - 6%
Output voltage 380/400/415V
Regulation + / - 1% for Line & Load variation (within Input Range & Load capacity)
Indications Mains ON
Input Voltage Low
Input voltage High
Other Indications for Optionals
Metering Voltmeter with selector switch on all phases to indicate Input / output phase voltage
Optionals MCB on Input / Output
Output voltage high / low cut off with auto recovery
Output Overload Alarm / tripping with delay
Ammeter on output
Single phasing Preventor with Alarm / Tripping
Phase sequence reversal protection
Servo By pass switch
General Specifications
Cooling Natural Air or Forced Ventilation or Oil Cooling (depending on rating)
Cabinet Table Top / Free standing (depending on rating)
Ambient Temp. 0 - 45 deg. C
Relative Humidity Max. 95% non condensing
Installation Indoor, in well ventilated space



Oil Cooled Three Phase Servo Stabilizers

Sterling Systems Sterling Systems

Air Cooled Three Phase Servo Stabilizers

Sterling Systems Sterling Systems


Electroplating Rectifier

Sterling Systems
Precision Electroplating Rectifiers are designed to provide Precisely controlled DC output for highly consistent Electroplating. The output voltage and output current (in CVC & CCC systems respectively) remain highly stabilized against AC Input Voltage variation from 170-270V and variation in job sizes. The system employs phase control technique using SCR's for control of output parameters.

Technical Specifications

A C Input Voltage 180-270V, 1Phase, 50Hz + / - 6%
DC Output voltage 6V to 100V
DC Output Current 10 to 100 A
Output Ripple (rms) Less than 5%
Output control
(Any one option to be selected)
Constant voltage control (CVC)
Constant current control (CCC)
User selectable CVC/CCC
Metering

(Any one option to be selected)
Digital Voltmeter & Ammeter for output voltage/Current
Digital meter with selector to indicate Output Voltage/Current
Protection AC fuse / MCB for mains short circuit
Auto resetting Electronic shut down for short circuit on output.
Optionals
(Any one option to be selected)
999 min or 999 sec. Timer
999 min / 999 sec. user selectable timer
Ah or milli Ah meter cum Controller
Indications Mains ON
System ON
voltage Control
Current Control
Cycle Over / Other indications for optionals
General Specifications
Cooling Natural Air or Forced Ventilation
(depending on rating)
Cabinet Table Top / Free standing (depending on rating)
Ambient Temp. 0 - 45 deg. C
Relative Humidity Max. 95% non condensing
Installation Indoor, in well ventilated space


Electroplating Rectifier
Sterling Systems Sterling Systems


Rectifier
Sterling Systems Sterling Systems


Battery Chargers

Sterling Systems
We manufacture Battery Chargers of various types for different applications, such as automotive & generator batteries, power house & sub station batteries, fork lifts, golf trolleys & elevator power back-up batteries etc.

The different types of chargers that we manufacture are
  • Float Charger
  • Boost and Float Charger
  • Boost cum Float Charger
Technical Specifications:

AC Input 180 - 270 V, 50Hz. +/- 6%, 1 Phase
DC Output Voltage Boost up-to 2.7V/cell +/- 1%
Trickle at 2.25V/cell +/- 1%
DC Output Current 2A to 50A
Protections Mains short-circuit by Fuse/ MCB
Charger over load by Current Limiting
Battery reverse Connection (optional)
Indications Mains on
Battery Charging
Battery Charged
12 V Mode (Optional)
24 V Mode (Optional)
Battery Reverse (Optional)
General Specifications
Cooling Natural Air or Forced Ventilation (depending on rating)
Cabinet Table Top / Free standing (depending on rating)
Ambient Temp. 0 - 45 deg. C
Relative Humidity Max. 95% non condensing
Installation Indoor, in well ventilated space
Cabinet Table Top Type


Salient Features
  • Complete isolation between AC input & DC output.
  • Battery Reverse Protection (Optional).
  • Protection against short circuit on Charger terminals.
  • Constant Current Charging from 180 - 270V input and from fully discharged battery to final charging level.
  • Automatic change over to Constant Voltage mode after the battery voltage reaches Normal Charge level.